TM 9-2320-209-20-2-2
q
Put back cable that has come off of
discharge valve
Make sure valve and control levers
q
are in OFF positions. Refer to
T M 9-2320-209-10
Using 1/2-inch wrench loosen two
q
nuts on U-bolt
Slide cable end through U-bolt
q
and using pliers hold end tightly
Tighten two nuts on U-bolt using
q
1/2-inch wrench
Adjust cables. Refer to Vol 3,
q
chapter 18, para 18-25 or
18-27
Put back cable that has come off
control lever
Make sure valve and control lever
q
are in OFF positions. Refer to
T M 9-2320-209-10
Using 5/8-inch wrench loosen nut
q
Slide cable end through clamp
q
bolt and using pliers hold end
tightly
Tighten nut using 5/8-inch wrench
q
Adjust cables. Refer to Vol 3,
q
chapter 18, para 18-25 or 18-27
Z
Replace broken discharge valve control
cable
Refer to Vol 3, chapter 18, para
q
18-25 or 18-27
TA 114978
Figure 65-5 (Sheet 2 of 3)
65-17
|