TM 9-2320-209-20-1
Table 1-4. Organizational Preventive Maintenance Checks and Services Semiannual Schedule
for M50A1, M50A2, and M50A3 Water Tank Trucks - Cont
Item
Procedures
Item
To Be
Check for and Have Repaired,
No.
Inspected
Replaced, Adjusted as Necessary
4
3. Check that exhaust gases are bypassing
(cont)
exhaust system and are coming out at rear
of tank body.
4. Turn exhaust bypass fording valve handle (2)
all the way to right. Check that exhaust gases
have stopped coming out at rear of tank body.
5. Turn exhaust bypass fording valve handle (2)
all the way to left.
6. Push exhaust bypass valve control (1) to in
position.
7. Stop engine. Refer to TM 9-2320-209-10.
5
Exhaust bypass
CAUTION
system (M50A3)
Exhaust bypass system will overheat tank body if
there is less than 10 inches of water in either
compartment. Do this check as quickly as possible,
if water level is lower than 10 inches.
Check exhaust bypass system for proper opera-
tion as follows:
1. Start engine. Refer to TM 9-2320-209-10.
2. Pull exhaust bypass valve control (1) to out
position.
1-32