TM 3-6665-225-12
2-20. Pump Assembly
(4) Block 4, Column a. Enter date of entry.
(5) Block 4, Column b. Not applicable.
A modified DA Form 2408-1 (fig. 2-10), Equipment
(6) Block 4, Column c. Enter pump assembly
Daily or Monthly Log, is used to record the number
operating hours since last tubing replacement from
of pump operating hours since last tubing replace-
M43 detector unit daily log. Example: Pump as-
ment when a pump assembly is removed from an
sembly Serial No. 172 is removed from M43 Serial
M43 detector unit for maintenance. This form is
No. 0012 for maintenance. M43 total hours at time
kept with the pump assembly until it is reinstalled
of removal is 1507 hours (see fig. 2-9); pump opera-
in an M43 detector unit and the action recorded in
ting hours since last tubing replacement is 33 hours
the M43 detector unit log. The pump assembly log
(1507-1474). Entry in column 4c of pump DA Form
is then discarded.
2408-1 is 33 (see fig. 2-10).
a. Modification of DA Form 2408-1.
(7) Block 4, Columns d through j. Not applica-
(1) Block 2. Line out "REGISTRATION OR."
ble.
(2) Block 4. Line out "DAILY" and "MON-
(8) Block 4, Column k. Signature of individual
THLY" and add "SCHED. MAINT."
making entries.
(3) Block 4, Column c. Line out "READING
(9) Add a note to form stating "KEEP THIS
MILES" and add an asterisk (*) and "HOURS." Use
FORM WITH PUMP ASSEMBLY UNTIL PUMP IS
another asterisk (*) to explain at bottom of form
INSTALLED INTO AN M43 DETECTOR UNIT
that hours entered are "operating hours since last
AND THE ACTION RECORDED IN M43 DETEC-
tubing replacement."
TOR UNIT LOG." See figure 2-10.
b. Use of Modified DA Form 2408-1.
(10) Form is now completed. Attach form to
(1) Block 1. Enter "PUMP ASSEMBLY, M43
pump. Fold, wrap around pump, and secure with
DET."
rubber band, item 6, table 1-3.
(2) Block 2. Enter pump serial number.
(3) Block 3. Not applicable.
Change 2
2-17
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |