TM 9-6115-663-13&P
1. CRIMPED CONNECTIONS SHALL BE IN ACCORDANCE WITH MIL-STD-454, REQUIREMENT 19.
2. HOT STAMP "W", INDICATED IN WIRE LIST, AND "97403-13229E5811-"WITH APPROPRIATE DASH NO. ON
SLEEVING, FIND NO. 2, IN ACCORDANCE WITH MIL-M-60903. LOCATE AT MIDPOINT OF WIRE.
3. HOT STAMP INSULATION SLEEVING, FIND NO. 2, WITH WIRE ADDRESS, WITHIN 2 INCHES OF ITS
TERMINATIONS, IN ACCORDANCE WITH MIL-M-60903. THE ADDRESS CONSISTS OF THE FROM
TERMINATION, A DOUBLE HEADED ARROW, AND THE TO TERMINATION.
4. STRIP WIRE IN ACCORDANCE WITH WIRE LIST AND TIN EXPOSED CONDUCTOR FOR A DISTANCE OF .12 +/-
.03 INCHES FROM CONDUCTOR END IN ACCORDANCE WITH MIL-STD-2000.
Figure G-6. Power Leads W1-W5 (Sheet 1 of 2).