TM 9-6115-663-13&P
Section Il. EQUIPMENT DESCRIPTION
1-9 EQUIPMENT CHARACTERISTICS, CAPABILITIES, AND FEATURES.
1-9.1 Characteristics. Each generator set is mounted on a modified M200A1 2 1/2 ton, two-wheel
trailer. The modification to the basic M200A1 Trailer includes generator mounting rails, special
fenders, an accessory box, and fire extinguisher brackets. Refer to TM 9-2330-205-14&P for detailed
equipment characteristics about the M200A1.
1-9.1.1 Power Unit PU-805. The PU-805 has a Tactical Quiet Generator Set mounted on a single
modified trailer. The generator set is a DOD Model MEP-806A liquid-cooled, diesel engine driven unit,
with a load capacity of 60 kW at 50/60 Hz. Refer to TM 9-6115-645-10 for detailed equipment
characteristics about the generator set.
1-9.1.2 Power Unit PU-806. The PU-806 has a Tactical Quiet Generator Set mounted on a single
modified trailer. The generator set is a DOD Model MEP-816A liquid-cooled, diesel engine driven unit,
with a load capacity of 60 kW at 400 Hz. Refer to TM 9-6115-645-10 for detailed equipment
characteristics about the generator set.
1-9.1.3 Power Plant AN/MJQ-41. The AN/MJQ-41 Power Plant consists of two PU-805 Power Units,
a power cable and a switch box. The PU-805 Power Units have been identified as either unit A or unit
B. The Switch Box is mounted on unit A and the cable is stored on unit B. The characteristics are
the same as listed for the PU-805 in paragraph 1-9.1.1.
1-9.2 Capabilities and Features. The PU-805, PU-806, and AN/MJQ-41 are all mounted on the
same trailer. The towing vehicle is either a 2 1/2 ton 6x6 or 5 ton 6x6. Electrical outputs are provided
in paragraphs 1-9.2.1 through 1-9.2.3.
1-9.2.1 Power Unit PU-805. The electrical output of the PU-805 is as follows:
ELECTRICAL OUTPUT -60 Hz/50 Hz:
120/208 volts, three phase, 50 Hz . . . . . . . . . . . 172 amps
240/416 volts, three phase, 50 Hz . . . . . . . . . . . 86 amps
120/208 volts, three phase, 60 Hz . . . . . . . . . . . 208 amps
240/416 volts, three phase, 60 Hz . . . . . . . . . . . 104 amps
1-9.2.2 Power Unit PU-806. The electrical output of the PU-806 is as follows:
ELECTRICAL OUTPUT -400 Hz:
120/208 volts, three phase, 400 Hz . . . . . . . . . . 208 amps
240/416 volts, three phase, 400 Hz . . . . . . . . . . 104 amps
1-9.2.3 Power Plant AN/MJQ-41. The AN/MJQ-41 Power Plant consists of two PU-805 Power
Units, a power cable and a switch box.  The capabilities and features are the same as listed for the
PU-805 in paragraph 1-9.2.1.