Page Title: POWER PLANT REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-24-1-2
0295 00
POWER PLANT REPLACEMENT (Contd)
24.
Remove nut (12), lockwasher (13), STE/ICE-R lead 770-M (11), and ground cable 93 (14) from
starter ground stud (15). Discard lockwasher (13).
25.
Remove nut (16), lockwasher (17), STE/ICE-R lead 770-S (10), and lead 214 (18) from starter
solenoid (1). Discard lockwasher (17).
26.
Remove nut (6), lockwasher (5), positive cable lead 6 (4), harness lead 2 (3), and relay lead 14 (2)
from starter solenoid (1). Discard lockwasher (5).
27.
Remove nut (7), lockwasher (8), and STE/ICE-R lead 770-T (9) from starter motor (19). Discard
lockwasher (8).
28.
Remove clamp (29) and heater hose (24) from fitting (30).
29.
Remove screw (32), clamp (33), and hose (24) from fender (34).
30.
Remove two screws (21), washers (22), clamps (23), and hose (24) from engine (20).
31.
Remove clamp (36) and hose (37) from tube (26).
32.
Loosen nut (31) and remove tube (26) from adapter (27) on thermostat housing (28).
33.
Remove screw (35), washer (22), clamp (25), and tube (26) from engine (20).
2
3
4
5
6
1
7
8
~
9
10
11
19
18
12
17
16
15
13
14
0295 00-6