Click here to make tpub.com your Home Page

Page Title: PINTLE HOOK MAINTENANCE - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-361-24-2
0199 00
PINTLE HOOK MAINTENANCE (Contd)
PINTLE HOOK REMOVAL
1.
Remove cotter pin (21) from pintle hook (14) and nut (1). Discard cotter pin (21).
2.
Remove nut (1), washer (2), and pintle hook (14) from rear crossmember (4).
3.
Remove two locknuts (20), inner bracket (3), two screws (18), and outer bracket (19) from rear
crossmember (4). Discard locknuts (20).
PINTLE HOOK LATCH REMOVAL
1.
Remove cotter pin (16) from lock (11). Discard cotter pin (16).
2.
Remove two grease fittings (13) and (5) from drive pin (12) and screw (6).
3.
Remove cotter pin (10) from screw (6) and slotted nut (9). Discard cotter pin (10).
4.
Remove slotted nut (9), screw (6), and lock (11) from pintle hook (14).
5.
Remove drive pin (12), latch (7), and spring (8) from lock (11).
CLEANING AND INSPECTION
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near
heat, sparks, flame, or other ignition sources. Use mechanical
ventilation whenever product is used in a confined space, heated
above ambient temperatures, or agitated. Keep container sealed
when not in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes
with large amounts of water for at least 15 minutes or until
irritation subsides. Inhalation may cause irritation to upper
respiratory passages. DO NOT have food or drink in the vicinity.
Failure to comply may result in injury to personnel.
1.
Clean all parts with Skysol 100 and dry with clean rag.
2.
Inspect all parts for breaks and cracks. Replace all damaged parts.
3.
Inspect drivescrew (15) and chain (17) for damage. Replace drivescrew (15) or chain (17) if damaged.
4.
Inspect spring (8) for breaks or collapsed coils. Replace if damaged.
5.
Inspect for broken or missing chain (17) and drivescrew (15). Replace any broken or missing parts.
6.
Replace grease fittings (5) and (13) if broken or missing.
PINTLE HOOK LATCH INSTALLATION
1.
Install drive pin (12) until flush with inside edge of lock (11).
2.
Install spring (8) and latch (7) in lock (11) until drive pin (12) is flush with outside edge of lock (11).
3.
Stake both edges of lock (11) in four places to hold drive pin (12) in place.