0133 00
TRANSFER CASE CONTROLS AND LINKAGE MAINTENANCE (W/PTO) (Contd)
INSTALLATION
1.
Install PTO shift control lock (5) and spring (6) to PTO shift control handle (4) with screw (7) and
new locknut (8). Ensure PTO shift control lock (5) turns freely on PTO shift control handle (4).
2.
Install two lubrication fittings (2) on two mounting brackets (1) and install mounting brackets (1)
on PTO shift control shaft (11).
3.
Install new woodruff key (12) and lever (15) on PTO shift control shaft (11) with screw (16) and
new locknut (14).
4.
Install seal (13) on cab floor (9).
NOTE
Assistant will help with step 5.
5.
Install two mounting brackets (1) with PTO shift control shaft (4) on cab floor (9) with four
screws (3) and new locknuts (10).
3
16
2
15
3
2
4
1
5
14
6
1
11
12
7
13
8
10
9
0133 00-5