FIELD MAINTENANCE INSTRUCTIONS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
HOT WATER PERSONNEL HEATER BLOWER MOTOR RESISTOR REPLACEMENT
REMOVAL AND INSTALLATION
INITIAL SETUP:
Applicable Models
Equipment Condition
All
Parking brake set and wheels chocked
(TM 9-2320-361-10).
Materials/Parts
Battery ground cable disconnected
Two lockwashers (item 215, WP 0470 00)
REMOVAL
Remove two screws (4), lockwashers (3), and resistor (1) from firewall (2). Discard lockwashers (3).
INSTALLATION
1.
Install resistor (1) on firewall (2) with two new lockwashers (3) and screws (4).
2.
Connect battery ground cable (WP 0126 00).
3.
Turn on hot water heater switch (TM 9-2320-361-10) and check personnel heater operations.
4.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
1
2
~
4
3
END OF WORK PACKAGE