TM 9-2320-361-24-1
0064 00
SECONDARY AND FINAL FUEL FILTERS TESTING AND MAINTENANCE (Contd)
REMOVAL
Fuel Filter Head
1.  Disconnect battery ground cable (WP 0126 00).
CAUTION
Cap or plug all openings immediately after disconnecting lines
and hoses to prevent contamination. Remove cap or plugs prior
to installation. Failure to do so may result in damage to
equipment.
NOTE
Mark location of the fuel lines for installation.
2.
Disconnect three fuel lines (4) and fuel line (7) from three elbows (3) and elbow (8).
3.
Remove three elbows (3), elbow (8), and tee (9) from fuel filter head (2).
4.
Remove three nuts (6), lockwashers (5), and fuel filter head (2) from engine (1). Discard
Fuel Filters
NOTE
Some fuel filters have two bleeder valves.
Secondary and final fuel filters are removed the same way.
This procedure covers the secondary fuel filter.
1.
Remove bleeder valve (11) from fuel filter head (2).
2.
Remove sleeve nut (10), washer (23), and gasket (22) from fuel filter head (2). Discard gasket (22)
and washer (23).
3.
Remove secondary fuel filter housing (18) and gasket (21) from filter head (2). Discard gasket (21).
4.
Remove filter element (20) from secondary fuel filter housing (18). Discard filter element (20).
5.
Remove cotter pin (17) from center post (12). Discard cotter pin (17).
6.
Remove cup (13), gasket (14), washer (15), and spring (16) from center post (12). Discard
gasket (14) and washer (15).
7.
Remove drain valve (19) from secondary fuel filter housing (18).
CLEANING AND INSPECTION
WARNING
Skysol 100 mixture is combustible; DO NOT use or store near
heat, sparks, flame, or other ignition sources. Use mechanical
ventilation whenever product is used in a confined space,
heated above ambient temperatures, or agitated. Keep
container sealed when not in use.
Contact with Skysol 100 may cause skin irritation. Use
chemical-resistant gloves. In case of skin contact, remove any
contaminated clothing and wash skin thoroughly with soap and
water. Wash contaminated clothing before reuse. Eye contact
may cause irritation, tearing, or blurring of vision. Use face
shield or goggles when eye contact may occur. In case of eye
contact, flush eyes with large amounts of water for at least 15
minutes or until irritation subsides. Inhalation may cause
irritation to upper respiratory passages. DO NOT have food or
drink in the vicinity. Failure to comply may result in injury to
personnel.
1.
Clean all components with Skysol 100 and dry with clean rag.
2.
Inspect elbows (3) and (8), tee (9), and center post (12) for burrs and stripped threads.
3.
Inspect filter head (2) and filter housing (18) for burrs and scratches on mating surfaces.
0064 00-4