TM 9-2320-361-24-1
0023 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) (Contd)
Table 1. Preventive Maintenance Checks and Services (PMCS) (Contd).
ITEM
ITEM TO CHECK/
EQUIPMENT NOT
INTERVAL
PROCEDURE
NO.
SERVICE
READY/AVAILABLE IF:
7
Semiannually Engine stop
Stop engine (TM 9-2320-361-10).
control
AFTER ROAD TEST
Perform all after-operation weekly and
monthly checks in TM 9-2320-361-10
PMCS. Make the following inspections in
the order given, including kit items on
vehicles so equipped.
WARNING
Battery acid (electrolyte) is extremely
harmful. Always wear safety goggles
and rubber gloves when performing
battery maintenance. Severe injury will
result if acid contacts eyes or skin.
Failure to do so may result in injury to
personnel.
Do not smoke, have open flame, or make
sparks when performing battery
maintenance. Batteries may explode
causing severe injury to personnel.
Remove all jewelry such as rings, dog
tags, and bracelets. If jewelry or
disconnected battery ground cable
contacts battery post, a direct short can
result, causing damage to equipment or
severe injury to personnel.
8
Semiannually Batteries
a. Check specific gravity of each cell
before adding distilled water. Using
optical battery tester, which requires no
temperature compensation, check
specific gravity of electrolyte in each
cell (TM 9-6140-200-14).
Semiannually RPL
b. Clean and inspect battery cables
Semiannually
c. If specific gravity of any cell is below
1.255, battery must be replaced or
recharged. Add distilled water as
necessary after checking battery.
Charge batteries as necessary
(TM 9-6140-200-14).
9
Semiannually Air cleaner
Air cleaner
Test air cleaner indicator (1) for proper
indicator
indicator
operation:
inoperative or
Semiannually
a. Remove clamp and cap from air cleaner.
yellow band is not
b. Start engine (TM 9-2320-386-10) and
showing.
Semiannually
run at 1200 RPM.
0023 00-4