TM 9-2320-361-24-1
0016 00
SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTION ENGINE--REPROGRAMMABLE
(STE/ICE-R) TROUBLESHOOTING INTRODUCTION (Contd)
NOTE
If any error message not listed below is displayed, return
STE/ICE-R set to field maintenance for repair.
Table 3. Error Messages.
VTM
INTERPRETATION
READOUT
Technician has requested information that the VTM it does not have; for example, if the
E000
technician requests the VID number and it has not yet been entered.
E001
Nonexistent test number has been dialed into TEST SELECT switches.
E002
Required transducer is not connected.
E004
VID number or number of cylinders has not been entered.
E005
Transducer offset test was not performed.
E007*
Conflict between VID number dialed in and the number of cylinders dialed in.
VTM is not receiving required voltage signal for test selected. This error code is related only
E008
to starter and compression balance tests.
E009
Engine is not running at start of test.
E010*
Wrong VID number has been entered.
Throttle control was operated incorrectly during power test, taking too much time to
E011
accelerate or decelerate.
E012
CI pulse tachometer is missing.
E013
Bad data has been taken for the test in progress. Repeat test one time.
E014*
Wrong number of cylinders has been dialed into VTM.
E015*
No longer used. If E015 appears, turn in VTM for update.
E017
Engine is not running, or ignition adapter is broken or not properly connected.
Engine RPM or AC frequency test was terminated automatically to protect VTM.
E018
Termination is only after several minutes of no-signal operation. Most likely, VTM was left
on vehicle and engine stalled.
E020
No first peak was detected by VTM during peak-to-peak voltage test.
VTM cannot calculate results. Current is over current probe's range and VTM did not
E021
sample correct portion of data.
E022
External voltage was detected in circuit tested while measuring resistance.
E023
VTM's constant voltage source is not working.