MECHANICAL SYSTEMS TROUBLESHOOTING - DIRECT SUPPORT (Contd)
Table 10. Fuel Tank Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check dump drain valve for proper
1. If dump drain valve operation is
4. FUEL MIXED WITH
operation.
defective, remove sump assembly
WATER WHEN
and replace dump drain valves
DISPENSED
(WP 0267 00).
2. If dump drain valve operation is
not defective, disassemble sump
valve assembly and inspect
internal components (WP 0267 00).
3. If sump valve components are
defective, replace components
(WP 0267 00).
Table 11. Water Tank Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check transfer case power
If PTO is not operating, refer to
1. WATER WILL NOT
WP 0008 00, table 9, malfunction 2.
operations.
PUMP FROM
COMPARTMENTS OR
1. If discharge valve operation is
2. Check discharge valve operation
PUMPS SLOWLY
defective, remove and inspect
for selected compartment.
discharge valve internal
components (WP 0265 00).
2. If discharge valve internal
components are defective, replace
components (WP 0265 00).
3. Check delivery pump operation.
1. If delivery pump screen and filter
separator are not restricted,
remove and inspect delivery pump
internal components
(WP 0461 00).
2. If delivery pump internal
components are defective, replace
components (WP 0461 00).
Check discharge valve operation for
1. If discharge valve operation is
2. WATER WILL NOT
defective, remove and inspect
selected compartments.
GRAVITY DRAIN
discharge valve internal
FROM SELECTED
components (WP 0265 00).
COMPARTMENTS
2. If discharge valve internal
components are defective, replace
(WP 0265 00).
1. Check transfer case power takeoff
If transfer case PTO is not operating,
3. WATER TANK
refer to WP 0008, table 9,
operations.
COMPARTMENTS
malfunction 2.
CANNOT BE
SUCTION FILLED
1. If delivery pump screen and filter
2. Check delivery pump operation.
separator are not restricted,
remove and inspect delivery pump
internal components (WP 0461 00).
2. If delivery pump internal
components are defective, replace
components (WP 0461 00).