MECHANICAL SYSTEMS TROUBLESHOOTING - UNIT (Contd)
Table 5. Fuel System Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NO FUEL AT FUEL
WARNING
INJECTORS
Diesel fuel is flammable. Do not
perform troubleshooting checks
near open flame, sparks, or
electricity. Injury or death to
personnel may result.
Eye protection is required when
performing fuel system
troubleshooting checks. Failure to
wear eye protection may result in
injury to personnel.
Ignition switch must remain off
during fuel system
troubleshooting checks. Failure to
verify that ignition system is
turned off may result in injury or
death to personnel.
Adjust fuel shutoff for proper
1. Check fuel shutoff for proper
operating conditions (WP 0071 00).
operation.
Clear restrictions from fuel pump
2. Inspect fuel pump pickup tube
pickup tube (WP 0061 00).
for restrictions (WP 0061 00).
1. If final fuel filters are restricted
3. Check final fuel filters for
or defective, replace
restrictions (WP 0064 00).
2. If final fuel filters are not
restricted and problem persists,
refer to WP 0008 00, table 2,
malfunction 1.
Table 6. Personnel Hot Water Heater Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check to ensure engine reaches
If engine does not reach normal
PERSONNEL HOT WATER
normal operating temperature.
operating temperature, refer to
HEATER DOES NOT HEAT
WP 0006 00, table 4, malfunction 2.
CAB
2. Check personnel hot water
If personnel hot water heater hoses
heater for clogged, broken, or
are leaking or collapsed, replace
leaking inlet/outlet hoses.
3. Check for proper personnel hot
If control cables are bent or broken,
water heater control cable and
replace (WP 0249 00).
operation of heater, defroster,
and heater diverter vents and
doors.
4. Check heater blower motor and
If damaged, replace personnel hot
fan for proper operation
water heater (WP 0250 00).
(TM 9-2320-361-10).