Page Title: WATER DISCHARGE PIPE REPAIR (TRUCKS M50A2 AND M50A3).
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-209-34-2-2
17-33. WATER DISCHARGE PIPE REPAIR (TRUCKS M50A2 AND M50A3).
No special tools required
TOOLS:
Solvent, dry cleaning, type II (SD-2), Fed. Spec P-D-680
SUPPLIES:
PERSONNEL:
One
EQUIPMENT  CONDITION:  Truck parked, engine off, handbrake set.
Preliminary Procedure. Remove discharge pipe. Refer to
TM 9-2320-209-20.
b.
Cleaning, Inspection, and Repair.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame.  Keep a fire extinguisher nearby when
solvent is used.  Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
Clean discharge pipe (1) with dry cleaning solvent.
1.
2.
Check that discharge pipe (1) has no cracks or holes.
If discharge pipe (1) is damaged, throw it away and get new one.
3.
NOTE
Follow-on Maintenance Action Required:
Replace discharge pipe. Refer to TM 9-2320-209-20.
END OF TASK