Page Title: CENTRIFUGAL PUMP REPAIR (TRUCKS M49A1C, M49A2C, M50A1, M50A2, AND M50A3) - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-209-34-2-2
c.
Cleaning.
WARNING
Dry cleaning solvent vapors can be harmful if
inhaled.  Work in well ventilated area.  Dry
cleaning solvent is flammable. Do not use near
open flame.  Keep fire extinguisher nearby.
Dry cleaning solvent will dry and crack skin.
Wear gloves when working with solvent.
CAUTION
Do not spin bearing at any time. Spinning will
seriously damage bearings.
After cleaning, keep bearings clean and dry.
Dirt and moisture can damage bearings.
NOTE
All old lubricant must be taken off bearings dur-
ing cleaning. Do soaking and clapping steps
over as necessary to take off all old lubricant.
(1) Using degreaser and solvent, soak bearing to loosen lubricant.
(2) If lubricant is left on bearing after soaking, clap bearing against heel
of hand to loosen lubricant.
(3) Air dry bearing.