Click here to make tpub.com your Home Page

Page Title: DELIVERY PUMP STRAINER AND GASKET REMOVAL AND REPLACEMENT
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-209-20-3-3
FRAME 2
1.
Take out strainer (1) from strainer housing (2).
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when solvent
is used. Use only in well-ventilated places. Failure to
do this may result in injury to personnel and damage to
equipment.
2.  Using solvent, clean strainer (1). Dry with compressed air. Make sure
there is no dirt left in strainer.
3.  Using solvent, clean flange (3). Use scraper, if needed, to get off all
gasket pieces. Do not get any gasket pieces in strainer housing (2).
END OF TASK
18-150