Quantcast ALTERNATOR AND PULLEY REMOVAL AND REPLACEMENT - continued - TM-9-2320-209-20-3-10461

 

Click here to make tpub.com your Home Page

Page Title: ALTERNATOR AND PULLEY REMOVAL AND REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
ALTERNATOR AND PULLEY REMOVAL AND REPLACEMENT - continued - TM-9-2320-209-20-3-10460
Up
/.5ton/TM-9-2320-209-20-3-1 2-1/2-Ton 6x6 M44A1 and M44A2 Series Trucks (Multifuel) Truck Cargo: M35A1 M35A2 M35A2C M36A2 Manual
Next
ALTERNATOR AND PULLEY REMOVAL AND REPLACEMENT - continued - TM-9-2320-209-20-3-10462
TM 9-2320-209-20-3-1
FRAME 6
CAUTION
Be careful when putting positive cable terminal lug (1)
on terminal (2).  This cable goes to the battery. The
lug is larger and more rounded on one side. This side
must go up.  Putting lug on the wrong way could short
out the alternator and damage it.
Put positive cable terminal lug (1) on terminal (2) as shown.  Put lockwasher
1.
(3) on terminal and screw on nut (4). Using torque wrench, tighten nut to
45 to 55 pound-inches.
2.
Put ground cable terminal lug (5) over hole in terminal block (6) as shown.
Put lockwasher (7) on bolt (8) and put bolt through terminal lug.
Screw bolt (8) into terminal block (6), and using torque wrench, tighten bolt
3.
to 82 to 102 pound-inches.