Quantcast THERMOSTAT  REMOVAL  AND  REPLACEMENT - continued - TM-9-2320-209-20-3-10398

 

Click here to make tpub.com your Home Page

Page Title: THERMOSTAT REMOVAL AND REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
THERMOSTAT  REMOVAL  AND  REPLACEMENT - continued - TM-9-2320-209-20-3-10397
Up
/.5ton/TM-9-2320-209-20-3-1 2-1/2-Ton 6x6 M44A1 and M44A2 Series Trucks (Multifuel) Truck Cargo: M35A1 M35A2 M35A2C M36A2 Manual
Next
Section IV. WATER PUMP
TM 9-2320-209-20-3-1
FRAME 5
Aline hole in rod end clevis (1) with hole in bracket (2) by moving radiator (3).
1.
Put bolt (4) through clevis (1) and bracket (2). Using 9/16-inch wrenches,
2.
screw on and tighten locknut (5) on bolt.
Make sure clamps (6) are positioned squarely on hose (7). Using screwdriver,
3.
tighten two clamp screws (8).
NOTE
Follow-on Maintenance Action Required:
Fill cooling system. Refer to para 6-10.
1.
2.
Start engine. Refer to TM 9-2320-209-10.
3.
Run engine until operating temperature is reached.
Check that engine temperature levels off between
160 and 180 as indicated on temperature gage.
Check hose fitting on thermostat and radiator
for leaks.
4.
Stop engine.  Refer to TM 9-2320-209-10.
5.
Close hood and side panels. Refer to
TM 9-2320-209-10.
END OF TASK